Trouble Shooting - Sky Sorter

TROUBLE SHOOTING

  • Home
  •   >   Trouble Shooting

NO EXPLANATION NEEDED, THANKS!

Machine has fault self-checking function, all the failed parts have corresponding alarm display, and may lead to machine stop. If so, please solve as below methods, if still can not be working, please Notify supplier immediately. users can solve general fault by himself, except for microcomputer control system breakdown.

  • The vibrator not working:

    • 1. Bad or fuse burned circuit

      btn-normal btn-hover

      Repair or replace the fuse tube circuit.

  • Ejector leak:

    • 1. Ejector have foreign matter

      btn-normal btn-hover

      Blowback, Repeated testing valve.

    • 2. Ejector part wear

      Replacement

  • Ejector not shooting:

    • 1. The ejector wire connect not well.

      btn-normal btn-hover

      Check with wires connected to ejector.

    • 2. Ejector core broken

      btn-normal btn-hover

      Replacement

    • 3. Control circuit board broken

      btn-normal btn-hover

      Replacement

  • Ejector shooting weak

    • 1. Ejector not in the specified position

      btn-normal btn-hover

      Re-adjust or replacement

    • 2. Pressure low

      btn-normal btn-hover

      Check pressure gage

  • Material jump

    • 1. Humidity is too big

      btn-normal btn-hover

      Dehumidification or Dry

    • 2. Chute is dirty

      btn-normal btn-hover

      Use soft thing to clean chute

    • 3. Chute scratches

      btn-normal btn-hover

      Replacement

  • Display light and Ejector high frequency.

    • 1. Led broken or poor connection

      btn-normal btn-hover

      Check led and line connection

    • 2. Sorting model choose wrong

      btn-normal btn-hover

      Choose correct sorting model

    • 3. Led power broken

      btn-normal btn-hover

      Change led power

    • 4. Background panel stuck

      btn-normal btn-hover

      Repair

    • 5. Background wave not adjust well

      btn-normal btn-hover

      Readjust background panel

  • Circuit fault tips

    • 1. Circuit fault

      btn-normal btn-hover

      Contact us

  • Almost not sorting

    • 1. Sensitivity low

      btn-normal btn-hover

      Re-adjust

    • 2. Background plate wrong adjustment

      btn-normal btn-hover

      Re-adjust

  • Sorting performance worse and worse over a period of time

    • 1. dust in sorting glass.

      btn-normal btn-hover

      Cleaning glass and change brush

    • 2. Sensitivity, background panel data change

      btn-normal btn-hover

      Re-adjust

    • 3. Chutes without heating

      btn-normal btn-hover

      check heating system

    • 4. Brush damage

      btn-normal btn-hover

      Replacement

  • The single side performance not well

    • 1. Cylinder cleaning not good,poor performance.

      btn-normal btn-hover

      Adjust the brush and speed

  • Often shut down

    • 1. Sensitivity too high

      btn-normal btn-hover

      Re-adjust

    • 2. Background plate waveform not well

      btn-normal btn-hover

      Re-adjust

    • 3. Impurity is too much

      btn-normal btn-hover

      Reduce capacity

    • 4. Lack of air pressure

      btn-normal btn-hover

      check the air pressure,air path,and re-adjust

    • 5. Pressure often protection

      btn-normal btn-hover

      Keep the air path smooth or change filter element.